Search
Products/Services
Flow Meters – Open Channel
Flo-Dar™ Flow Meter
Flo-Dar™ Overview Page
Flo-Dar™ Animation
Request Quote / More Info
Rental Information
Specifications
» Flo-Dar™ / Flo-Station
» Flo-Dar™ XT / Flo-Logger
» Flo-Dar™ / Flo-Logger
Literature Download
Flo-Dar™ Portable Data Sheet
Flo-Dar™ Permanent Data Sheet
Flo-Dar™ XT Remote Communication Data Sheet
Understanding Flo-Dar™
Flo-Dar™ Start-Up Guide
Flo-Dar™ User Manual

Instr. Sheet -Temporary mount assembly for Flo-Dar™

Instr. Sheet - Laser alignment tool for Flo-Dar™
Instr. Sheet - Surcharge Velocity Sensor (SVS) to Flo-Dar™ Installation
Instr. Sheet - Using Flo-Logger to pace a Hach Sigma SD900 Sampler
Instr. Sheet - Cable Installation for MMI Flo-Logger
Flo-Logger Portable Monitor User Manual - English
Flo-Logger Portable Monitor User Manual - Spanish

Flo-Logger Portable Monitor User Manual - French

Flo-Station (AC/DC) Monitor User Manual

Customer Testimonials

There were two major reasons why we chose the Flo-Dar’s. One reason was the ease of installation and the fact that there really wasn’tmuch as far as maintenance that we had to do on them. They are pretty self-contained and there’s not a lot the operator has to do except read them on a monthly basis and take a look at the data. Secondly, it was a safety issue for our personnel. ~City of Kennewick

“The biggest benefit to Rehrig was the immediate cost savings. Costing data indicated that the payback for the meter was less than one year. “The meter has a high degree of accuracy and it’s definitely easy to download” ~ProChem

Flo-Dar’s ability to monitor flow out of the stream itself was the main reason we chose the meter. After the initial installation we have had no need to go in the hole for cleaning. ~ELCO

Marsh-McBirney FLO-DAR™ with Flo-Station™ Radar Velocity/Area Flow Meter

Specifications

FLO-DAR SENSOR (Without SVS)

Enclosure
IP 68 Waterproof rating, Polystyrene

Dimensions
160.5 W x 432.2 L x 297 D mm (6.32 x 16.66 x 11.7 in.), with SVS, D = 387 mm (15.2 in.)

Weight
4.8 kg (10.5 lbs.)

Operating Temperature
-10 to 50°C (14 to 122°F)

Storage Temperature
-40 to 60°C (-40 to 140°F)

Power Requirements
Supplied by Flo-Station

Interconnecting Cable
ˆDisconnectable at both sensor and logger
Polyurethane, 0.400 (±0.015) in. diameter; IP68
Standard length 9M (30 ft), maximum 305 m (1000 ft)

Certification
FCC Rules Part 15, Subpart C; Industry Canada RS-S210
(No user license required)

SURCHARGE DEPTH MEASUREMENT

Auto zero function maintains zero error below 0.5 cm (0.2 in.)

Method
Piezo-resistive pressure transducer with stainless steel diaphragm

Range
3.5 m (138 in.), overpressure rating 2.5 x full scale

VELOCITY MEASUREMENT

Method
Radar

Range
0.23 to 6.10 m/s (0.75 to 20 ft/s)

Frequency Range
24.075 to 24.175 G-Hz, 15.2mW (max.)

Accuracy
±0.5%; ±0.03 m/s (±0.1 ft/s)

DEPTH MEASUREMENT

Method
Ultrasonic

Standard Operating Range from Flo-Dar Housing to Liquid
0 to 152.4 cm (0 to 60 in.)

Optional Extended Operating Range from Transducer
Face to Liquid
0 to 6.1 m (0 to 20 ft.) with 43.18 cm (17 in.) dead band, temperature compensated.

Accuracy
±1%; ±0.25 cm (±0.1 in.)

FLOW MEASUREMENT

Method
Based on Continuity Equation

Accuracy
±5% of reading typical where flow is in a channel with uniform flow conditions and is not surcharged, ±1% full scale max.

SURCHARGE CONDITIONS DEPTH/VELOCITY

DEPTH (Std with Flo-Dar Sensor)
Surcharge depth supplied by Flo-Dar sensor.

VELOCITY (Optional Surcharge Velocity Sensor)

Method
Electromagnetic

Range
±4.8 m/s (±16 ft/s)

Accuracy
±0.15 ft/s or 4% of reading, whichever is greater.

Zero Stability
> ±0.05 ft/s

FLO-STATION PERMANENT AC/DC POWERED ELECTRONICS

Data Storage
64K (16K cycles of velocity/depth data)

Local Terminal
RS232C at 19.2K baud

Optional Display
Dimensions: 1 in. x 3 in. Four lines of text display, FLOW, LEVEL, VELOCITY, FLOW TOTAL or any combination of any four channels containing data. Screens may be programmed to alternate values displayed.

Time-Based Accuracy
1 second per day

Outputs
Four 4-20 mA outputs: system-isolated, up to 600 ohm load. Outputs are flow, level, velocity or surcharge level.

Contact Closure
Dry contact closure with adjustable duration selectable for flow-proportional or alarm based on: FLOW, LEVEL, VELOCITY, SURCHARGE LEVEL, TEMPERATURE, BATTERY VOLTAGE, EACH SAMPLE, BAD SAMPLE OR ANALOG INPUT.
Rating: 1A @ 30 Vdc (resistive) 0.5A @ 125 Vac (resistive)

Power Requirements
AC: 85-264 Vac, 47-63 Hz, 32 watts
DC: 12 Vdc for Flo-Station without display or Flo-Station with display (backlight off) 180 mA (2.1 watts) with (1) 4-20 mA utilized.

Housing
Material: ABS plastic, NEMA 4
Dimensions: 257.8 W x 236.7 H x 95.3 D mm (10.15 W x 9.32 H x 3.75 D in.)
Weight: 2.3 kg (5 lbs)

Operating Temperature
Operating Range: -10 to 50°C (14 to 122°F)
-20 to 50°C (-4 to 122°F) without display

Storage Temperature
Without Display: -40 to 60°C (-40 to 140°F)
With Display: -20 to 60°C (4 to 140°F)

Set-up/Data Retrieval

Flo-Ware for Windows software is the user on-site set-up, data management, and report generation software. It is compatible with desktop/portable computers utilizing Windows 95/98/2000/Me/NT/XP. Flo-Ware FX for PocketPC has all the same functionality as Flo-Ware for Windows with the exception of report generation.